tdc vka150, Elektronika, Zasilacze i przetwornice AC-DC DC-DC noty katalogowe EDW, Noty zasilacze, Murata Power ...

[ Pobierz całość w formacie PDF ]
Corporate: www.cdtechno.com
Product: www.cdpoweronline.com
VKA150MS
150 Watt Single Output Half Brick DC/DC Converter
Operation to +100°C Baseplate
Temperature
Primary Remote On/Off, Choice of
Pos/Neg Logic
Adjustable Output Voltage
Continuout Short-Circuit Protection
Thermal Shutdown
Case Ground Pin
33 - 75V Input Range
High Efficiency: 85% Typical at
5V
100µS Transient Response 50-
100%Load Step
420 kHz Fixed-Frequency
Operation
Remote Sense
UL/CUL 1950, VDE EN60950
The VKA150MS Series DC/DC
converters present an economical
and practical solution for distrib-
uted power system architectures
which require high power density
and efficiency while maintaining
system modularity and
upgradeability. With the ability to
operate over a wide input voltage
range of 33 to 75 volts, these
modules are ideal for use in
battery backup applications com-
mon in todays' telecommunication
and electronic data processing
applications. The output is fully
isolated from the input, allowing
for a variety of polarity and
grounding configurations.
The VKA150MS's proprietary
control circuitry responds to 50-
100% load steps in 100µSeconds
to within 1% nominal Vout.
The patented fixed frequency
architecture combined with sur-
face mount technology results in a
compact, efficient and reliable
solution to DC/DC conversion
requirements. Safety approvals per
UL/CUL 1950, EN 60950
PRODUCT SELECTION CHART
MODEL
INPUT
VOUT
IOUT
EFFICIENCY
VOLTAGE
(VDC)
(A)
MIN
TYP
VKA150MS05
48VDC
5.0V
30.0
84
85
VKA150MS12
48VDC
12.0V
12.5
88
89
VKA150MS15
48VDC
15.0V
10.0
88
89
VKA150MS24
48VDC
24.0V
6.25
89
90
VKA150 MSzz -
Device Family
Indicates 150 Watt Regulated Unit
Model Number
Selected from Table of Electrical Characteristics
Where:
zz = Output Voltage (05=5V, 12=12V,15=15V,etc.)
Lead Length
0.200" - No Number
0.145" - (6)
0.110" - (8)
Remote On-Off Logic:
Positive - No Number
Negative - (1)
Product: www.cdpoweronline.com
1
VKA150MS Rev C 1/2004
SPECIFICATIONS, ALL MODELS
Specifications are at T
CASE
= +40°C Nominal Input Voltage unless otherwise specified.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
48 75 V
DC
Maximum Input Current
V
IN
= 30V
DC
6.6
A
Reflected Ripple Current
Peak - Peak
550
mA
Input Ripple Rejection
DC to 1KHz
50
60
dB
No Load Input Current MS
100
mA
Power Dissipation MS
No Load
4.8
W
Standby, Primary On/Off
Disabled MS
0.4
W
Inrush Charge
V
IN
= V
IN
max
0.360
mC
Quiescent Operating Current
Primary On/Off Disabled
8
12
mA
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
OUTPUT
Rated Power
150
W
Set point Accuracy
1
%
Line Regulation
High Line to Low Line
0.02
0.05
%
Load Regulation
No Load to Rated Load
0.2
0.5
%
Output Temperature Drift
±.02
±.05
%/°C
Output Ripple, p-p
DC to 20MHz BW
1.5%
V
OUT,
Nom
Output Current Limit Inception
105%
130%
150%
l
OUT,
Nom
Output Short-Circuit Current
120%
150%
l
OUT,
Nom
Output Overvoltage Limit
120%
140%
V
OUT,
Nom
Transient Response
50 to 100% Load Step
Peak Deviation
di/dt = 0.1A/
μ
Sec
2
3%
V
OUT,
Nom
Settling Time
V
OUT,
1% of Nominal Output
75
100
μ
Sec
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
ISOLATION
Input to Output
Peak Test for 2 Seconds
1500
V
DC
Input to Baseplate
1500
V
DC
Output to Baseplate
500
V
DC
Resistance
10
M
Ω
Capacitance
2000
pF
Leakage Current
V
ISO
= 240V
AC
, 60Hz
180
μ
A, rms
GENERAL
Switching Frequency
400
420
440
KHz
Remote Sense Compensation
0.5
V
Output Voltage Adjust Range
5V
-40% / +10%
V
OUT,
Nom
12V
-50% / +10%
V
OUT,
Nom
15V
-50% / +10%
V
OUT,
Nom
24V
-50% / +10%
V
OUT,
Nom
Remote On/Off Control Inputs
Primary
Open Collector/Drain
Sink Current-Logic Low
1.0
mA
Vlow
0.4
V
Vhigh
Open Collector
Turn-on Time
Within 1% of Rated Output
5.0
8.0
mSec
Weight
3 (85)
oz (g)
TEMPERATURE
Operation/Specification
Case Temperature
-40
+25
+100
°C
Storage
Case Temperature
-55
+25
+125
°C
Shutdown Temperature
Case Temperature
+100
+115
°C
Thermal Impedance, case-ambient
8.2
°C/W
Lead Solder Temperature 10 Seconds max
+300
°C
NOTES:
(1) See Typical Performance Curves, page 3
(2) Continuous Mode
(3) See graphs for Efficiency vs. Output Load, V
IN
, T
CASE
(4) 3.3V Models Limited in Trim Down Range
(5) Consult Factory for Details
Product: www.cdpoweronline.com
2
VKA150MS Rev C 1/2004
MECHANICAL
NOTES:
All dimensions are in inches (millimeters).
PIN PLACEMENT TOLERANCE: ± 0.005"
MECHANICAL TOLERANCE: ± 0.015"
Marked with: specific modeL ordered, date code, job code.
MATERIAL: Units are encapsulated in a low thermal resistance
molding compound which has excellent chemical resistance
and electrical properties in high humidity environments and
over a wide operating temperature range. The encapsulant
and outer shell of the unit have UL94V-0 ratings. Lead
material is solder plated to allow ease of solderability.
0.530 MAX
[13.46]
0.20 [5.1]
.040 [1.02] DIA.
7 PLACES
.081 [2.06] DIA.
2 PLACES
0.20 [5.1]
0.50 [12.7]
.400 [10.16]
0.40 [10.16]
2.000
[50.80]
0.700
[17.78]
VKA150MS
1.000
[25.40]
1.000
[25.40]
2.40
[61.0]
MAX
1.400
[35.56]
1.400
[35.56]
MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES
MAX. TORQUE, 8 IN/LBS
1.900
[48.26]
0.19 [4.8]
2.28
[57.91]
MAX
OUTPUT ADJUST VOLTAGE
OVP NOTE
This feature allows the user to accurately adjust the
module's output voltage set point to a specified level.
This is achieved by connecting a resistor or potentiometer
from the TRIM terminal to either the +Vout terminal (for
increased Vout) or the -Vout terminal (for decreased
Vout). The formulae below describe the trim resistor
value to obtain a Vout change of
Special attention should be given to the peak voltage
deviation during a dynamic load step when trimming
the output above the original set point to avoid
tripping the overvoltage protection circuit. Should an
OVP condition occur, the converter will go into a
latch condition and must be externally reset before it
will return to normal operation.
Δ
%. V
O
is output
voltage prior to adjustment (3.3V, 5V, 12V, 15V, or 24V).
(
Vo(100 +
Δ
%)
_
(100 + 2
Δ
%)
)

Radj - up =
Δ
Δ
1.225
%
%
Radj - down =
(
100
-
2
)

Δ
%
Product: www.cdpoweronline.com
3
VKA150MS Rev C 1/2004
Power Electronics Division, Americas
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.295-4197
C&D Technologies, EMEA/AP
Milton Keynes MK14 5BU UK
Tel: +44 (0)1908 615232
Fax: +44 (0)1908 617545
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be
accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or
completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby
disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from
any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in
user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.
Product: www.cdpoweronline.com
4
VKA150MS Rev C 1/2004
  [ Pobierz całość w formacie PDF ]

  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • shinnobi.opx.pl